PECHORIN'S home   account   archive   eshop   globalmediapro
.
.


Post new message


Home | Previous message

Re: 99% guaranteed solution of JVC DV107 unit in safeguard message problem solution

JB38 Posted Jan 26, 2009, in response to:ugur

On any model other than D followed by two digit models this problem is caused in 90% of cases by the mechanism not returning to its fully stopped position properly after carrying out and operation, thereby not activating the appropriate sensor. The thumping operation jolts the mechanism into the proper position whereby the sensor can send the signal to the mechanism that all is normal, as beforehand the logic circuits acted as though the mechanism had jammed whilst conducting various operations, like loading or unloading etc. Sometimes (only sometimes) even just pressing slightly on the cassette door can correct the fault.